Do Not Use Flag Applied To Final Measurements Even When NEW Read Is Invalid (Doc ID 1534491.1)

Last updated on MARCH 25, 2013

Applies to:

Oracle Utilities Meter Data Management - Version 2.0.1.7 and later
Information in this document applies to any platform.

Symptoms

Consumption exceed threshold exception is not thrown when a normal measurement with higher measurement condition overrides the existing normal measurement.

Steps to Recreate

1. Create measurements for following dates

End Date TimeReadingCondition Codes
 10-14-2011 00:00:00 100 501000
 10-15-2011 00:00:00 250 501000
 10-16-2011 00:00:00 300 501000
 10-31-2011 00:00:00 500 501000
 11-30-2011 00:00:00 800 501000
 12-13-2011 00:00:00 1100 501000
 12-15-2011 00:00:00 1500 501000

2. End new reading for date given below

End Date TimeReadingCondition Codes
 12-01-2011 00:00:00 650 901000

3. New IMD will move to finalized satte. No error was thrown.

End Date TimeReadingCondition Codes
10-14-2011 00:00:00 100 501000
10-15-2011 00:00:00 250 501000
10-16-2011 00:00:00 300 501000
10-31-2011 00:00:00 500 501000
11-30-2011 00:00:00 800 501000 DO NOT USE
12-01-2011 00:00:00 650 901000
12-13-2011 00:00:00 1100 501000
12-15-2011 00:00:00 1500 501000

 

Cause