Auto Reconciliation of Circuit Design not Kicking after a new Network System is Added. (Doc ID 1558735.1)

Last updated on FEBRUARY 22, 2017

Applies to:

Oracle Communications MetaSolv Solution - Version 6.0.15 to 6.2.1 [Release 6.0.15 to 6.2.0]
Information in this document applies to any platform.

Symptoms

PROBLEM DEFINITION:

Users reporting that Connection Reconciliation is not kicking automatically when a Network System is added to the Connection Design for a ST01 facility
circuit riding an OC12 Network.

Prior to that the existing Network System was deleted/removed due to business reasons.


WORKAROUND
==========
Reconcile the facility assignment in the rider circuit by removing and then
adding back the facility block to the design, as in the following sample:


BUSINESS IMPACT
===============
Manual intervention for something that should be done automatically.

Cause