High/Low Check VEE Rule Calculations and Scalar Estimation Rule Calculations Can be Incorrect in Version 2.1 (Doc ID 1585207.1)

Last updated on SEPTEMBER 17, 2013

Applies to:

Oracle Utilities Meter Data Management - Version 2.1.0 and later
Information in this document applies to any platform.

Symptoms

There is a difference in calculation in the High/Low check VEE rule between MDM 2.0.1.x and 2.1.0.x. The correct calculation occurs in the 2.0.1.x version.  This problem occurs when there are multiple Measuring Components with the same Unit of Measure on a Device Configuration.  The calculation incorrectly includes other measuring components in the calculation even when there has not been a meter exchange and the measuring components are for different UOM/TOU/SQI combinations.

This same issue can also be seen when using Scalar Estimations.

Changes

 This issue began occuring with the 2.1 release.

Cause