Allocations Fail with Terminate Called After Throwing an Instance of 'RWBoundsErr' Errors After Upgrading to PFT 6.1 (Doc ID 1640753.1)

Last updated on APRIL 09, 2014

Applies to:

Oracle Financial Services Profitability Management - Version 6.1.0.3 and later
Information in this document applies to any platform.
Oracle Financial Services Analytical Applications Infrastructure (OFSAAI)
Oracle Financial Services Analytical Applications (OFSAA)

Symptoms

On Oracle Financial Services Profitability Management (PFT) 6.1.0.3 when running an existing allocation from 6.0, the allocation does nothing. Running the allocation from the command line gives the following error:

ERROR
Terminate called after throwing an instance of 'RWBoundsErr'

The generated PFT debug log ends abruptly:

Debug log ends abruptly:

Module Logging OFS Access module data: select
select FSI_IDT_ALLOC_V.sys_id_num, FSI_IDT_ALLOC_V.sequences,
FSI_IDT_ALLOC_V.alloc_type, FSI_IDT_ALLOC_V.parallel_flag,
FSI_IDT_ALLOC_V.audit_trail_flag, FSI_IDT_ALLOC_V.process_target,
FSI_IDT_ALLOC_V.alloc_description, FSI_ALLOC_LEAVES.alloc_sys_id,
FSI_ALLOC_LEAVES.sequences, FSI_ALLOC_LEAVES.data_filter_sys_id,
FSI_ALLOC_LEAVES.row_number, FSI_ALLOC_LEAVES.leaf_num_id,
FSI_ALLOC_LEAVES.leaf_node, FSI_ALLOC_LEAVES.row_type,
FSI_ALLOC_LEAVES.tree_sys_id, FSI_ALLOC_LEAVES.tree_level_num,
FSI_ALLOC_LEAVES.constant_char,
FSI_ALLOC_LEAVES.suppress_mirror_flg,
FSI_ALLOC_LEAVES.alloc_dim_subtype_cd,
FSI_ALLOC_LEAVES.dimension_value_char,
FSI_ALLOC_LEAVES.expression
from FSI_IDT_ALLOC_V, FSI_ALLOC_LEAVES
where FSI_IDT_ALLOC_V.sys_id_num = FSI_ALLOC_LEAVES.alloc_sys_id
and FSI_IDT_ALLOC_V.sequences = FSI_ALLOC_LEAVES.sequences
and FSI_IDT_ALLOC_V.sys_id_num = 270558.00000
order by FSI_IDT_ALLOC_V.sequences, FSI_ALLOC_LEAVES.row_number,
FSI_ALLOC_LEAVES.alloc_dim_subtype_cd,
FSI_ALLOC_LEAVES.leaf_num_id

New allocations created after upgrade do not have any issue.

Steps to reproduce

The issue can be reproduced at will with the following steps:
1. Run upgraded from 6.0 allocation.

Changes

Upgrade to PFT 6.1.x version from PFT 6.0 version.

Cause