EGRC 865.1616: Access Sync Failed. (Doc ID 1674873.1)

Last updated on JANUARY 19, 2016

Applies to:

Oracle Application Access Controls Governor - Version 8.6.5 to 8.6.5 [Release 8]
Information in this document applies to any platform.

Symptoms

On : 8.6.5.1616 version, Acces sync issue

When attempting to run Access synchronization hob, the following error occurs.

ERROR in catalina.out
-----------------------
5:50:29 PM com.sunopsis.dwg.dbobj.SnpSession treatSession
SEVERE: Agent encountered an error: ODI-1217: Session LOADACCESSDATACORE (4154) fails with return code 12899. Caused by: ODI-1226: Step LoadMenus_i2 fails after 1 attempt(s).
ODI-1217: Session LOADACCESSDATACORE (4154) fails with return code 12899.
ODI-1226: Step LoadMenus_i2 fails after 1 attempt(s).
ODI-1240: Flow LoadMenus_i2 fails while performing a Loading operation. This flow loads target table TMP_FND_MENUS_VL.
ODI-1228: Task SrcSet0 (Loading) fails on the target ORACLE connection physical_schema_tgt.
Caused By: java.sql.BatchUpdateException: ORA-12899: value too large for column "GRC"."C$_0TMP_FND_MENUS_VL"."C6_USER_MENU_NAME" (actual: 81, maximum: 80)


STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Login to GRC 865 application
2. Run access sync
3. Monitor the job and check catalina.out file.

BUSINESS IMPACT
-----------------------
The issue has the following business impact:
Due to this issue, users cannot run Access sychronization job.