How to Force a Connect Operation Instead of a Continue After a Redirection of Service ?
(Doc ID 1900275.1)
Last updated on MARCH 12, 2019
Applies to:
Oracle Communications Converged Application Server - Service Controller - Version 6.1.0 and laterInformation in this document applies to any platform.
Goal
For a scenario with a simple redirection service which adds a prefix to the CdPN and monitors the call. If the call setup fails, a fallback feature makes a new attempt without the prefix.
For the fallback attempt, OCCAS-SC must generate a CAP Connect, but since no parameters are modified, a CAP Continue is created, causing the MSC to Continue the call attempt WITH the previously set prefix.
How can we force OCCAS-SC to generate a Connect from that 302 (without updating the CgPN or CdPM)?
Solution