Synchronize Page Edge Feature is not Working with DPM Activated for the Workbook (Doc ID 1909381.1)

Last updated on AUGUST 17, 2016

Applies to:

Oracle Retail Predictive Application Server - Version 13.4.1.14 and later
Information in this document applies to any platform.

Symptoms

When Dynamic Position Maintenance (DPM) is activated for a hierarchy, and there are 2 hierarchies in the Z-axis that should get synchronized across the worksheets in the Fusion Client, only the first hierarchy on that axis is getting synchronized across the pages upon user changes. The other hierarchy does't get synchronized.

Consider the following example with Promotion and Location on the Z-Axis. If a new workbook is created and the user changes the Location Dimension position first, then only the Location hierarchy gets synced and the Promotion is never synced. If a new workbook is created and the first position changed is on the Promotion hierarchy, then only the Promotion hierarchy gets synced and the Location will be never be in sync.

Cause