lgv_sel_run and Additional ECI-Calls Lead To Issues With the Actions Executed in the LogiView Procedure (Doc ID 2021440.1)

Last updated on MARCH 08, 2017

Applies to:

Oracle Agile Engineering Data Management - Version 6.1.1.0 and later
Information in this document applies to any platform.

Symptoms

ACTUAL BEHAVIOR
--------------------------

Find LogiView procedure for selected document records called with lgv_sel_run runs more than once after executing eci_upd_typ with the CAD-Integration.
The main Logiview procedure calls another sub procedure with lgv_sel_run.


EXPECTED BEHAVIOR
--------------------------------
Same behavior before and after calling eci_upd_typ

STEPS:
---------------------
1. Create at least 2 new 3D_MODEL documents prt0001, prt0002
2. Create 1 new DRAWING document prt0003-drw
3. Open general document list
4. Load and select at least two existing records - e.g. prt0001, prt0002 typ: 3D_MODEL
5. Execute main LogiView procedure from button select menu - calling it with lgv_sel_run
6. Receive output - row info and document_id for each selected record
7. Execute eci_test to read input file "eci_test.txt " (includes eci commands)eci_test_vc10.exe in existing general document list
8. Select again at least two existing records - e.g. prt0001, prt0002
9. Execute main LogiView procedure from button select menu again - calling it with lgv_sel_run
10. Receive output - row info and document_id for each selected record
11. Find output for 2.nd selected record is printed twice


Cause