XDS CCD Import Does Not Store Effective Time For Supply Act (Doc ID 2023292.1)

Last updated on JUNE 12, 2017

Applies to:

Oracle Healthcare Data Repository - Version 7.0.1 and later
Information in this document applies to any platform.

Goal

On HDR 7.0.1 version,

When using ITI-41 with import mode to import CCD with Equipment Section that contains supplyAct, it was found that effectiveTime of the SupplyAct is not stored.

ACTUAL BEHAVIOR  
---------------
EffectiveTime of the SupplyAct is not stored.

EXPECTED BEHAVIOR
-----------------------
EffectiveTime of the SupplyAct  should be stored into database.

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1) persist attached CCD document containing medical equipment section with 2 supplyActs containing effective time  using ITI-41 import.
2) query database for the effectiveTime of the supplyActs using:

3) find that the effective time columns are all null.
 

Solution