BRM 7.5 Pipeline Fails to Start with HttpServer Module Configured

(Doc ID 2055108.1)

Last updated on DECEMBER 18, 2017

Applies to:

Oracle Communications Billing and Revenue Management - Version to [Release 7.5.0]
Linux x86-64


On : 7.5 PS11 version, Pipeline Manager


HttpServer Module is configured in registry file. Same registry file is able to start in 7.5 with 166 output streams without commenting HttpServer, but fails with 167 output streams.

7.4 to 7.5 upgrade : Pipeline is not starting up in 7.5 with below error.

Pipeline should start without any issues.

The issue can be reproduced at will with the following steps:

1. Configure HttpServer block.

2. Configure SequencerPool block with more than 510+ sequencer.

3. Start the pipeline.

4. Pipeline will fail to start with above error