BRM 7.5 Pipeline Fails to Start with HttpServer Module Configured (Doc ID 2055108.1)

Last updated on JULY 15, 2016

Applies to:

Oracle Communications Billing and Revenue Management - Version 7.5.0.0.0 to 7.5.0.0.0 [Release 7.5.0]
Linux x86-64

Symptoms

On : 7.5 PS11 version, Pipeline Manager

ACTUAL BEHAVIOR
---------------

HttpServer Module is configured in registry file. Same registry file is able to start in 7.5 with 166 output streams without commenting HttpServer, but fails with 167 output streams.

7.4 to 7.5 upgrade : Pipeline is not starting up in 7.5 with below error.



EXPECTED BEHAVIOR
-----------------------
Pipeline should start without any issues.


STEPS
-----------------------
The issue can be reproduced at will with the following steps:

1. Configure HttpServer block.

2. Configure SequencerPool block with more than 510+ sequencer.

3. Start the pipeline.

4. Pipeline will fail to start with above error



Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms