MSS Allows User To Change The Circuit ID After The Circuit Has Been “Record Issued”
(Doc ID 2067331.1)
Last updated on MARCH 07, 2019
Applies to:
Oracle Communications MetaSolv Solution - Version 6.2.1 and laterInformation in this document applies to any platform.
Symptoms
On : 6.2.1 version, Engineering
ACTUAL BEHAVIOR
-----------------------
MSS allows user to change the circuit ID after the circuit has been “Record Issued” . Test was performed for ISR Virtual Circuits
STEPS
--------
The issue can be reproduced at will with the following steps:
1.Create an ISR order with request type `X-Broadband Services and enter the number of virtual connection.
2) Create a Virtual circuit in Virtual Circuits tab (Free format/Structured format) : BB/10001/UPLINK/XXXXXKXA/YYYYYYBN
3) Assign provisioning plan which has DLRD task.
4) Open DLRD task and change status as `Record Issued¿ via connection design window.
5) Go to ISR order and navigate to Virtual Circuits tab. Open the virtual circuit and try to edit the Circuit Id (ECCKT). It will allow you to edit the circuit id. The new Circuit Id BB/10001/UPLINK/XXXXXKXA/YYYYYYBN will also be reflected in the order.
Changes
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |
References |