Facility Assignment Blocks are Showing Equipment on one Side

(Doc ID 2307287.1)

Last updated on SEPTEMBER 26, 2017

Applies to:

Oracle Communications MetaSolv Solution - Version 6.2.1 and later
Information in this document applies to any platform.

Symptoms

Facility assignment blocks show all equipment on one side of the facility block even though the facility circuit is properly assigned to the originating and terminating locations.

In the Connection Design window, the Facility Assignment blocks show all equipment on one side of the facility block even though the facility circuit is properly assigned to the originating and terminating locations. This issue occurs when the first 8 bytes of the originating location matches the first 8 byte of the terminating location.

 

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1-Equipment assignment to a facility circuit.



 ### Patch Information ###
We are at version 6.2.1.1135.14

 ### Additional Information ###
We found this issue is caused by A_Z_OTHER_CD for enabled ports not matching the main port assignment in the PORT ADDRESS table. When an equipment assignment is made at the A or Z location the enabled ports should match. Attached are examples.
 