Adding a Crew to a Safety Document Stops Tag Point Recording

(Doc ID 2324865.1)

Last updated on NOVEMBER 28, 2017

Applies to:

Oracle Utilities Network Management System - Version 2.3.0.0.0 to 2.3.0.0.0 [Release 2.3]
Oracle Network Management for Utilities - DMS - Version 2.3.0.0.0 to 2.3.0.0.0 [Release 2.3]
Information in this document applies to any platform.

Symptoms

Adding a crew to a safety document stops Tag Point recording.

After adding devices to the Tag Points table leave the Record button on and add a safety crew. When returning to adding device(s) to the Tag Points table devices aren’t recorded. The Record button needs to be toggled Off/On to continue recording.

STEPS
1. Open safety document
2. Turn Tag Points table Record On
3. Add device(s) from viewer
4. Add Crew to assigned Crews table
5. Record is still on for tag points. Go to viewer to add another device. Will not add device. Have to turn Record off and then on

The following error would appear in the client log.

ERROR SAFETY: [] Config error. Missing recordCondActKey config for device selections.