Unable To Hide All Analog Values Displayed For A Device (Doc ID 2639278.1)

Last updated on MARCH 12, 2021

Applies to:

Oracle Utilities Network Management System - Version 2.4.0.1.0 to 2.4.0.1.0 [Release 2.4]
Oracle Network Management for Utilities - DMS - Version 2.4.0.1.0 to 2.4.0.1.0 [Release 2.4]
Information in this document applies to any platform.

Symptoms

On : 2.4.0.1.0 version, Web Workspace


An operator is able to choose which measurements they want displayed (or hidden) in the viewer via the SCADA Summary tool.

If you have a default value for visible analog measurements (set in x_conditions.sql), you cannot hide all of the measurements for an object, otherwise the configured default gets displayed again.


You should be able to hide all visible analog measurements for an object in the viewer, regardless of what is specified in the CONDITION_RULES table.


The issue can be reproduced at will with the following steps:
1. Navigate to a device that has analog measurements being displayed
2. Remove Amps A, Amps B, Amps C, and Amps N via the SCADA summary tool for the device
3. Notice when the last measurement is removed all the defaulted on measurements return


For example, product_conditions.sql has these three entries specified:

INSERT INTO condition_rules (condition, class, priority, location, status, devsymbol_num, symbol_num)
    VALUES ('analog','object', 0 , 1 , -1 , 1013 , -1 );
INSERT INTO condition_rules (condition, class, priority, location, status, devsymbol_num, symbol_num)
    VALUES ('analog','object', 0 , 1 , -1 , 1014 , -1 );
INSERT INTO condition_rules (condition, class, priority, location, status, devsymbol_num, symbol_num)
    VALUES ('analog','object', 0 , 1 , -1 , 1015 , -1 );

Those devsymbol_num's correspond to these three attributes:
kVA_A            1013    1     6      Phase A Power (kVA)||1
kVA_B            1014    1     6      Phase B Power (kVA)||1
kVA_C            1015    1     6      Phase C Power (kVA)||1


So, by default, all three kVA phase values are shown.
As soon as an operator hides all three kVA phase measurements (via the SCADA Summary tool), all three measurements re-appear.

Cause