My Oracle Support Banner

When actual Meter Turn off read from SOM activity is not aligned with US End Date/Time then IMD is created in exception state (Doc ID 2645704.1)

Last updated on OCTOBER 10, 2022

Applies to:

Oracle Utilities Customer to Meter Base - Version 2.6.0.1.0 and later
Oracle Utilities Meter Data Management - Version 2.2.0.2.0 to 2.3.0.2.0 [Release 2.2 to 2.3]
Information in this document applies to any platform.

Symptoms



Meter Turn off read from SOM is going to IMD Exception with Inactive Measurement Check Rule

Workaround-
Manually Override Exception on the IMD to finalize the read


Steps-
1.Create Master data setup for Scalar Measuring Component and install/Connect device. Associate Usage Subscription to it.
2.Turn off Meter Activity is created for the above Service Point.
3.Usage Subscription has an end date/time of 2019-01-01-00.00.00
4.Read is collected on 2019-01-01-02.00.00 as that is when the US was actually turnedoff. This is valid to customer.
5.Attach Inactive Measurement Check Rule to VEE Group and plug it on the MC with the following configuration:Check for Missing Usage Subscription Relationship - Yes
6.Submit the below data on Scalar Measuring Component:

Measurement Date/Time     Quantity   MSRMT_COND_FLG

1/12/2018 12:00:00           0             501000


7.Submit an IMD for 1/1/2019 02:00:00 with quantity 20.8.Notice that IMD goes into exception. Customer is expecting an enhancement fix to allow this scenario and not throw an exception as it’s a valid scenario in their case.

Changes

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.