My Oracle Support Banner

Archiver Destination For WebCenter Content Fails On Installation With Default Settings (Doc ID 2659785.1)

Last updated on APRIL 16, 2020

Applies to:

Oracle Documaker - Version 12.6 and later
Information in this document applies to any platform.

Symptoms

In ODEE 12.6.2 and ODEE 12.6.3, when a WebCenterContent destination is added to Archiver using the out of the box settings as configured in the ODEE installer. On the UCM Details screen of the installer, the user is prompted for a Connection String. The default connection string is http://localhost:4444. The installation guide says of this setting, "Enter the connection string. Here is an example: idc://hostname:4444". If the default connection string is used, even adjusting for appropriate server name and port, the Archiver will fail with "oracle.documaker.archiver.Archiver.initConnector: Connector failed to initialize oracle.documaker.ecmconnector.connectorapi.exceptions.FrameworkInitializationException: Required constructor execution failed - oracle.documaker.ecmconnector.ucmdestination.UCMDestination - java.lang.NoClassDefFoundError: org/apache/commons/httpclient/HttpConnectionManager". In order to work properly, the Connection String must be set to idc:// protocol. The default string on the installer should be changed to idc://

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Cause
Solution
References


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.