Fields Not Sync Using D1-ODMSPSyncRequest Initial Sync
(Doc ID 2692361.1)
Last updated on SEPTEMBER 24, 2022
Applies to:
Oracle Utilities Customer to Meter Base - Version 2.7.0.3.0 to 2.7.0.3.0 [Release 2.7]Information in this document applies to any platform.
Symptoms
On : 2.7.0.3.0 version, Installation and Patching
ACTUAL BEHAVIOR
---------------
Fields not sync using D1-ODMSPSyncRequest Initial Sync
EXPECTED BEHAVIOR
-----------------------
Fields should be sync using D1-ODMSPSyncRequest Initial Sync
STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Take note of the discrepancy between the business object xpath elements. Since these are mapped to BO_DATA_AREA they need to be the same.
D1-ServicePointODMBORead X1D-ServicePoint
siteLocation deviceLocation
siteLocationDetail deviceLocationDetails
spInstructionDetail spInstructionDetails
What is happening now is that the fields in the MDM SP are not being extracted even if they are populated:
• deviceLocation
• deviceLocationDetails
• spInstructionDetails
2. Testing
Service Point
SP ID: <input ID>
Run Batch F1-SYNIL
Batch run completed successfully.
3. Outbound Sync Request
Notice that the extracted fields are blank:
• siteLocation
• siteLocationDetail
• spInstructionDetail
4. Inbound Sync Request
Notice that the fields are blank:
• siteLocation
• siteLocationDetail
• spInstructionDetail
5. Run Batch F1-SYSRQ
Batch run completed successfully.
6. Results
Sync Request transitioned to Data Transformed / Basic Schema Validation
Site Location (Device Location), Site Location (Device Location) Detail and SP Instruction Detail are blank.
Cause