Application Hangs Indefinitely After Clicking on a Connection Design > CLR/DLR Design Assignment Block of "Unknown"
(Doc ID 2760234.1)
Last updated on SEPTEMBER 25, 2024
Applies to:
Oracle Communications MetaSolv Solution - Version 6.3.1 and laterInformation in this document applies to any platform.
Symptoms
When a user clicks on a Connection Design > CLR/DLR Design assignment block of "Unknown", the application hangs indefinitely and the tbs.exe process consumes between 25% to 35%. The problem manifests itself when the assignment block clicked on by the user has a corresponding NULL ASAP.DLR_CIRCUIT_DESIGN_LINE.BLOCK_IND value in the database. These blocks are displayed as a type of "Unknown" although it should be noted that records with a BLOCK_IND of 'OLD' are also displayed as a type of "Unknown", but the application does not hang when they are selected by a user.
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |
References |