My Oracle Support Banner

Custom Report Publish Error In Unifier - " The system could not process your request. Contact your Administrator" (Doc ID 2762874.1)

Last updated on MARCH 24, 2021

Applies to:

Primavera Unifier - Version 17.12.0.0 and later
Information in this document applies to any platform.

Symptoms

On : 17.12.0.0 version, Unifier Integration

Error in publishing custom reports in Unifier through BI Publisher

ERROR
-----------------------
The system could not process your request. Logging in again may help in some cases. Contact your administrator if you are still having problems.

Unifier.log has below error

#### 2021-03-21 16:37:50,943 <unifier_log> <ERROR> #t<[ACTIVE] ExecuteThread: '8' for queue: 'weblogic.kernel.Default (self-tuning)'> #x<8373076139577547170> #c<Target.Exception> unifier:/sys/bip/report/runReport throws an exception at file:///sys/bip/action.xml:2636:
java.lang.NoSuchMethodError: com.sun.xml.ws.api.message.Message.getHeaders()Lcom/sun/xml/ws/api/message/HeaderList;
at org.apache.chemistry.opencmis.commons.impl.tube.client.WssMUTube.processResponse(WssMUTube.java:59)


STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1.Login to Unifier
2.Go to Custom Template
3.Try to publish any of the Custom template
4.Observe error

Changes

 Migrated/Upgraded Primavera Unifier Application

Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Changes
Cause
Solution


My Oracle Support provides customers with access to over a million knowledge articles and a vibrant support community of peers and Oracle experts.