Terminate Request after SIM Change failed with DIAMETER_RATING_FAILED
(Doc ID 2833666.1)
Last updated on FEBRUARY 15, 2024
Applies to:
Oracle Communications BRM - Elastic Charging Engine - Version 12.0.0.3.0 and laterInformation in this document applies to any platform.
Symptoms
On Oracle Communications Elastic Charging Engine (ECE), 12.0.0.3.0 version, Rating business logic
ACTUAL BEHAVIOR:
---------------------
When a Subscriber Identity Module (SIM) change is done for a Subscriber in Network and Billing and Revenue Management (BRM), it is observed that the Terminate Request for the existing Session (for the old SIM) is getting failed with DIAMETER_RATING_FAILED.
Response received from ECS:
The number of Stale Sessions are getting increased due to this issue.
EXPECTED BEHAVIOR:
-----------------------
After Subscriber Identity Module (SIM) Change, for the old International Mobile Subscriber Identity (IMSI) which is an existing session, the Terminate Request should be Successful.
STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Create an account.
2. Initiate a session by sending CCR-I Message.
3. Update a session by sending CCR-U Message.
4. Do the SIM Change via API Call "PCM_OP_DEVICE_ASSOCIATE" and un-pair the old SIM and pair the new SIM.
5. Terminate a session by sending a CCR-T Message with old SIM and check if it is getting failed with Result Code "Diameter Rating Failed"