Ongoing IE/SP Sync Going To Update Or Pre-add Error Creating Partial IE/SP Records In The UI
(Doc ID 2899625.1)
Last updated on SEPTEMBER 30, 2022
Applies to:
Oracle Utilities Customer to Meter Base - Version 2.8.0.0.0 and laterOracle Utilities Meter Data Management - Version 2.4.0.0.0 and later
Information in this document applies to any platform.
Goal
On : 2.8.0.0.0 version, Meter Data Management
Ongoing IE/SP sync going to update or pre-add error creating partial IE/SP records in the UI
Ongoing IE/SP sync going to update or pre-add error creating partial IE/SP records in the UI. Want to understand why primary key and record would be created if the sync is not going to synchronized. This is affecting UAT/ORT sync request numbers, as well as causing error in the F1-SYNRQ batch for the corresponding outbound syncs that are generated and will always error due to incomplete information
Bug 34579506 - ONGOING IE/SP SYNC GOING TO UPDATE OR PRE-ADD ERROR CREATING PARTIAL IE/SP RECORDS IN THE UI
Problem Cause
A null pointer is encountered in D1-DETIECHG validation algorithm logic when origStartDateTime value is null and its value is being compared to newStartDateTime value.
Solution