My Oracle Support Banner

Capacity On Resources In Planner's Workbench Is Not Accurate When Using Simulation Set. (Doc ID 2939766.1)

Last updated on JUNE 20, 2023

Applies to:

Oracle Materials Requirement Planning - Version 12.2.6 and later
Information in this document applies to any platform.

Symptoms

The Current view in the planners workbench (navigation: Material Planning /  Workbench / Horizontal Plan) is not being adjusted by the utilization % on the adjustment units, so the current capacity is not correct because it is getting the full brunt of the units adjustment.

Example:
Resource: RES1
Base capacity is 2 units x 8 hrs x 43.75% utilization =7

Used simulation set to adjust units down by -.6
Snapshot and Job/Resource Workbenches: 2 units -.6 units=1.4 x 8 hours x 43.75% utilization = 4.9
Current is: 7 Base Capacity – (.6 adjusted units x 8 hours) = 2.2



Cause

To view full details, sign in with your My Oracle Support account.

Don't have a My Oracle Support account? Click to get started!


In this Document
Symptoms
Cause
Solution