Argus Upgrade To 8.4.2 Fails In Step Changelogs/bridge/prerequisite_checks.xml::7::safety-upgrade Due to Duplicate Entries in Filestore
(Doc ID 3049222.1)
Last updated on SEPTEMBER 24, 2024
Applies to:
Oracle Life Sciences Argus Safety - Version 8.4.2 and laterInformation in this document applies to any platform.
Goal
Argus upgrade to 8.4.2 fails when executing bridge/841/factorydata/bulk.xml
The fix for Bug 36093338 - Upgrade fails when there is a common documentum_id is present in more than 1 case resolved the below issue:
Problem Description
Upgrade fails when there is a common documentum_id is present in more than 1 case. This issue was observed due to duplicate records created in ARGUS_BRIDGE.FILE_STORE table due to merging the data from CASE_NOTES_ATTACH table.
This was fixed in 8.4.2 upgrade scripts to eliminate duplicate entries in ARGUS_BRIDGE.FILE_STORE table by using the DISTINCT statement.
However, it can still fail if there are also multiple file types or filenames for the same ID.
For example on a query against the case_notes_attach table:
|--------|----------------|---------------------------------------------------------------------------------------------------------|
|3 |0902bc39818292b4|Literature_J1805463 |
|1 |0902bc39818292b4|Literature_J1805463.pdf
Solution
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Goal |
Solution |
References |