Discrepancies Reopening When Comparing Dates In RDC Onsite (Doc ID 741488.1)

Last updated on MAY 28, 2010

Applies to:

Oracle Clinical Remote Data Capture Option - Version: 4.5.3 and later   [Release: 4.5 and later ]
Information in this document applies to any platform.
***Checked for relevance on 28-May-2010***

Symptoms

A validation procedure comparing the visit date reopens immediately once the discrepancy was
resolved in on-site. The data from the VALIDATION_REPORTED_VALUES table show that one instance the Visit date has a 2 digit year and the next instance the visit date has a 4 digit year.

The validation procedures that we have seen this situations contain the following in the
expression: “rxc_date.convert(E.EXTL_DATA_D) !=VISIT_DATE”.

The reopening of discrepancies appears to occur for on-line and batch validation execution.

Steps To Reproduce:

  • Create an external sample date discrepancy where a validation procedure exists for that data.
  • Resolve it and save it.
  • IF the does not create it then create the discrepancy in either RDC PDF/classic or OC discrepancy management then from on-site, resolve the discrepancy.


Cause