Symptoms

On AERS 4.6:
Intermittently after selecting 'Pick DT' from the Case--> Events--> Interactive Coding Form
the following error occurs:

ERROR

FRM-92101: There was a failure in the Forms Server during startup. This could happen due to
invalid configuration.
Please look into the web-server log file for details.



Details...
Java Exception:
oracle.forms.net.ConnectionException: Forms session <92> aborted: unable to communicate with
runtime process.
at oracle.forms.net.ConnectionException.createConnectionException(Unknown Source)
at oracle.forms.net.HTTPNStream.getResponse(Unknown Source)
at oracle.forms.net.HTTPNStream.doFlush(Unknown Source)
at oracle.forms.net.HTTPNStream.flush(Unknown Source)
at java.io.DataOutputStream.flush(Unknown Source)
at oracle.forms.net.StreamMessageWriter.run(Unknown Source)


When the error occurs the AERS Application hangs and must be killed.

Steps To Reproduce:

  1. Log into AERS
  2. Navigate to Case
  3. Events
  4. Enter an event that does not code
  5. 'Interactive Coding Form' will come up
  6. Search for a event and click 'Pick DT'
  7. Verify 'Operation Completed' is returned and select 'OK'.
  8. FRM-92101 error will be returned.


Cause