Dynamic Data Set (DDS) With Enabled-Required Child DE of Type Pull-Down Passes Validation Without a Value Selected (Doc ID 2163939.1)

Last updated on JULY 25, 2017

Applies to:

Primavera Unifier - Version 10.1 to 10.1 [Release 10.1]
Primavera Unifier Cloud Service - Version 10.1 to 10.1 [Release 10.1]
Information in this document applies to any platform.

Symptoms

On Unifier : Version 10.1.19.0

ACTUAL BEHAVIOR
----------------------
For a Dynamic Data Set (DDS) where the Master Data Element (MDE) is a radio button whose selection determines the enabling-required, and disabling-not required, of two child Data Elements (DE's); a Data Picker and a Pull-Down menu. When the MDE is selected to 'Yes' the Data Picker gets enabled-required, and the Pull-Down menu is disabled-not required. When the MDE is selected to "No" it is vice versa.

EXPECTED BEHAVIOR
-----------------------
When the MDE is selected as 'No', and the user does not pick some value for the enabled-required child DE of type Pull-Down the user should not be able to Send the record along to the next step in the workflow.

BUSINESS IMPACT
-----------------------
The issue has the following business impact:
Due to this issue, the user is able to Send the record along to the next step of in the workflow without selecting a value for the enabled-required child DE.

Cause