HALRT-02011: Flash disk poor performance status
(Doc ID 1206015.1)
Last updated on AUGUST 12, 2022
Applies to:
Oracle Exadata Storage Server Software - Version 11.2.1.3.1 to 11.2.3.2.0 [Release 11.2]Information in this document applies to any platform.
Symptoms
Sun Oracle Exadata Storage Server is equipped with four PCIe cards. Each card has four flash disks (FDOMs) for a total of 16 flash disks. The 4 PCIe cards are present on PCI slot numbers 1, 2, 4, and 5. The PCIe cards are not hot-pluggable such that Exadata Cell must be powered down before replacing the flash disks or cards.
You may need to replace a flash disk because the flash disk is in poor performance status.
To identify a poor performance flash disk, use the following command:
CellCLI> LIST PHYSICALDISK WHERE DISKTYPE=flashdisk AND STATUS= 'warning - poor performance' DETAIL
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |