Production Database Is Not Coming Up due to ORA-235
(Doc ID 1266376.1)
Last updated on JANUARY 17, 2023
Applies to:
Oracle Exadata Hardware - Version 11.1.0.7 and laterInformation in this document applies to any platform.
Symptoms
Node fails to start the database.
Database startup failing with following error after unexpected failure
ORA-00235: control file read without a lock inconsistent due to concurrent update
Sat Nov 13 09:11:03 2010
Reconfiguration started (old inc 252, new inc 254)
List of nodes:
0 1 2 3 4 5 6 7
Global Resource Directory frozen
Communication channels reestablished
Master broadcasted resource hash value bitmaps
Non-local Process blocks cleaned out
Error: Controlfile sequence number in file header is different from the one in memory
Please check that the correct mount optionsare used if controlfile is located on NFS
ARC0 (ospid: 26460): terminating the instance
Sat Nov 13 09:11:03 2010
Reconfiguration started (old inc 252, new inc 254)
List of nodes:
0 1 2 3 4 5 6 7
Global Resource Directory frozen
Communication channels reestablished
Master broadcasted resource hash value bitmaps
Non-local Process blocks cleaned out
Error: Controlfile sequence number in file header is different from the one in memory
Please check that the correct mount optionsare used if controlfile is located on NFS
ARC0 (ospid: 26460): terminating the instance
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |
References |