My Oracle Support Banner

Downstream Capture Creation Failed with ORA-01653 (Doc ID 1423436.1)

Last updated on DECEMBER 20, 2019

Applies to:

Oracle Database - Enterprise Edition - Version 10.2.0.1 to 11.2.0.3 [Release 10.2 to 11.2]
Oracle Database Cloud Schema Service - Version N/A and later
Oracle Database Exadata Cloud Machine - Version N/A and later
Oracle Database Exadata Express Cloud Service - Version N/A and later
Oracle Cloud Infrastructure - Database Service - Version N/A and later
Information in this document applies to any platform.

Symptoms

During the recreation of a Downstream capture process, operation fails with the following errors:


ORA-01653: unable to extend table SYS.LOGMNRG_OBJ$ by 128 in tablespace SYSTEM
ORA-06512: at "SYS.DBMS_LOGMNR_INTERNAL", line 5786
ORA-06512: at "SYS.DBMS_LOGMNR_INTERNAL", line 5884
ORA-06512: at "SYS.DBMS_CAPTURE_ADM_INTERNAL", line 861
ORA-06512: at "SYS.DBMS_CAPTURE_ADM", line 496
ORA-06512: at "SYS.DBMS_STREAMS_RPC_INTERNAL", line 13
ORA-06512: at "SYS.DBMS_STREAMS_RPC", line 187

Cause