Exadata : After Disk Replacement, GridDisks are Not Added Back to ASM DiskGroup Automatically (Doc ID 1464217.1)

Last updated on JULY 02, 2017

Applies to:

Oracle Exadata Hardware - Version 11.1.0.7 to 11.2.0.3 [Release 11.1 to 11.2]
Information in this document applies to any platform.

Goal

Scenario
=======

User issues a Drop Disk command from ASM, Disk gets dropped from the ASM Disk Group.

Rebalance starts and finishes successfully.

Post this, the same cell disk goes into Predective Failure state.

At this time,
cellsrv will issue drop of griddisk at ASM side for the disks which are known to cellsrv,
and not for the disks which were dropped manually.

After the Disk Replacement,
Grid Disks which were dropped manually from the ASM DiskGroup, before the failure, will not be added back.
Grid Disks which were dropped by Cellsrv will be added back to ASM diskgroups.



 

Solution

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms