DataPump Fails To Start And Reports Error ORA-31648 Timeout Before Master Process DM00 Finished Initialization (Doc ID 1475574.1)

Last updated on NOVEMBER 28, 2016

Applies to:

Oracle Server - Enterprise Edition - Version 11.2.0.2 to 11.2.0.2.0 [Release 11.2]
Information in this document applies to any platform.

Symptoms

When trying to start a DataPump job, the following errors are reported and the job does not start:

ORA-31626: job does not exist
ORA-31637: cannot create job SYS_EXPORT_TABLE_01 for user ORACLE
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 95
ORA-06512: at "SYS.KUPV$FT", line 1569
ORA-39062: error creating master process DM00
ORA-31648: Timeout before master process DM00 finished initialization.

Cause