ORA-39125 and ORA-00904 When Using Data pump Network_Link option (Doc ID 1533464.1)

Last updated on FEBRUARY 28, 2013

Applies to:

Oracle Database - Enterprise Edition - Version 10.2.0.5 to 11.2.0.3 [Release 10.2 to 11.2]
Information in this document applies to any platform.

Symptoms


When Using Data pump Network Link option fails with following errors:

Estimate in progress using BLOCKS method...
Processing object type SCHEMA_EXPORT/TABLE/TABLE_DATA
ORA-39125: Worker unexpected fatal error in KUPW$WORKER.GET_TABLE_DATA_OBJECTS while calling DBMS_METADATA.FETCH_XML_CLOB []
ORA-00904: : invalid identifier
ORA-06512: at "SYS.DBMS_METADATA", line 1886


Setting event 904 below to trace the error will results in following errors:

-- Alter system set events '904 trace name errorstack level 4';
-- Perform Data Pump operation with Network Link option

ORA-00904: : invalid identifier
ORA-06512: at "SYS.DBMS_METADATA", line 1886
ORA-06512: at "SYS.DBMS_METADATA", line 4410
ORA-02063: preceding 5 lines from DPM_RO2
BEGIN :1 := dbms_metadata.network_fetch_clob@DPM_RO2(:2,:3,:4,:5,:6,:7); END;


Cause

Sign In with your My Oracle Support account

Don't have a My Oracle Support account? Click to get started

My Oracle Support provides customers with access to over a
Million Knowledge Articles and hundreds of Community platforms