Installation of Oracle Database Client 12.1.0.1 fails on Windows 8 (32 bit) at System Architecture Check
(Doc ID 1579617.1)
Last updated on FEBRUARY 21, 2019
Applies to:
Oracle Database - Enterprise Edition - Version 12.1.0.1 and laterOracle Database Cloud Schema Service - Version N/A and later
Oracle Database Exadata Express Cloud Service - Version N/A and later
Oracle Database Exadata Cloud Machine - Version N/A and later
Oracle Cloud Infrastructure - Database Service - Version N/A and later
Microsoft Windows (32-bit)
Symptoms
Installation of Oracle Database Client 12.1 (32-bit) on Windows 8 (32-bit) fails during the System crchitecture check
INFO: Architecture: This is a prerequisite condition to test whether the system has a certified architecture.
INFO: Severity:CRITICAL
INFO: OverallStatus:VERIFICATION_FAILED
INFO: -----------------------------------------------
INFO: Verification Result for Node:xxxxx
INFO: Expected Value:64-bit
INFO: Actual Value:32-bit
INFO: Error Message:PRVF-7535 : Proper architecture is not found on node "xxxxx" [Expected = "64-bit" ; Found = "32-bit"]
INFO: Cause: System architecture does not meet the requirement.
INFO: Action: Ensure that the correct software bundle is being used.
INFO: Severity:CRITICAL
INFO: OverallStatus:VERIFICATION_FAILED
INFO: -----------------------------------------------
INFO: Verification Result for Node:xxxxx
INFO: Expected Value:64-bit
INFO: Actual Value:32-bit
INFO: Error Message:PRVF-7535 : Proper architecture is not found on node "xxxxx" [Expected = "64-bit" ; Found = "32-bit"]
INFO: Cause: System architecture does not meet the requirement.
INFO: Action: Ensure that the correct software bundle is being used.
Changes
Cause