ORA-38802 and ORA-01403 during Datapump Export (Doc ID 2118055.1)

Last updated on MARCH 18, 2016

Applies to:

Oracle Database - Standard Edition - Version 12.1.0.1 to 12.1.0.2 [Release 12.1]
Information in this document applies to any platform.

Symptoms

While trying to perform a Datapump export, the following errors are raised:

Processing object type SCHEMA_EXPORT/SEQUENCE/SEQUENCE
ORA-39126: Worker unexpected fatal error in KUPW$WORKER.FETCH_XML_OBJECTS [SEQUENCE:"TEST"."SEQUENCE_TEST"]
ORA-38802: edition does not exist
ORA-06512: at "SYS.DBMS_EDITIONS_UTILITIES", line 288
ORA-01403: no data found
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 95
ORA-06512: at "SYS.KUPW$WORKER", line 11014
----- PL/SQL Call Stack -----
  object line object
  handle number name
0x3fa4139f0 26217 package body SYS.KUPW$WORKER
0x3fa4139f0 11041 package body SYS.KUPW$WORKER
0x3fa4139f0 13189 package body SYS.KUPW$WORKER
0x3fa4139f0 3128 package body SYS.KUPW$WORKER
0x3fa4139f0 11737 package body SYS.KUPW$WORKER
0x3fa4139f0 2059 package body SYS.KUPW$WORKER
...
Job "SYSTEM"."SYS_EXPORT_SCHEMA_07" stopped due to fatal error at Mon Nov 16 12:35:14 2015 elapsed 0 00:02:10

 

There are no editions used in the database, except for the default one:

 

Changes

 Upgraded to 12.1.0.2 database version.

Cause