Data Pump Network Link Import from 11.2 to 12c Fails with ORA-39126 ORA-06502 ORA-06512 when Using High Parallelism (Doc ID 2118159.1)

Last updated on MARCH 21, 2016

Applies to:

Oracle Database - Standard Edition - Version 12.1.0.2 to 12.1.0.2 [Release 12.1]
Information in this document applies to any platform.

Symptoms

You are performing a data pump import (impdp) using a  NETWORK_LINK and when specifying PARALLEL = n+1 where "n" is the number of workers, it terminates with the following errors:

ORA-39126: Worker unexpected fatal error in KUPW$WORKER.MAIN [SELECT UNIQUE object_type FROM sys.ku$_oracle_supplied_obj_view]
ORA-06502: PL/SQL: numeric or value error: character string buffer too small
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 95
ORA-06512: at "SYS.KUPW$WORKER", line 11259


Setting PARALLEL=n (for example 64), it works without issue.

For example: if n=64 then 64+1 = 65 workers fails with the above error during a datapump network link import operation

Changes

The database has just been upgraded to 12c. This was not an issue in previous version.

Cause

Sign In with your My Oracle Support account