Data pump network_link import with private Database Link Fails with ORA-04054

(Doc ID 2128750.1)

Last updated on MARCH 02, 2017

Applies to:

Oracle Database - Enterprise Edition - Version and later
Information in this document applies to any platform.


Running import with network_link using private connect to database link.
Query across the dblink works fine.

A data import across same network_link works fine.
Only the TTS network_link import fails with this error.

impdp system/oracle network_link=DPLINK logfile=nettimp.log
directory=dp_test_dir transport_tablespaces=TBSL

Connected to: Oracle Database 12c Enterprise Edition Release - 64bit Production
With the Partitioning, OLAP, Advanced Analytics, Real Application Testing and Unified Auditing options
ORA-39006: internal error
ORA-39065: unexpected master process exception in DISPATCH
ORA-04054: database link DPLINK does not exist
ORA-39097: Data Pump job encountered unexpected error -4054