New Standby Database Does Not Get Mount After successful Switchover By Broker (Doc ID 2201322.1)

Last updated on NOVEMBER 07, 2016

Applies to:

Oracle Database - Enterprise Edition - Version 12.1.0.2 and later
Information in this document applies to any platform.

Symptoms

Single Node Primary and Physical Standby DB configured with Broker

Switchover is done by the Broker . Switchover is successful
 But while restarting the New Standby DB it fails with the below Errors :

sculkget: failed to lock /oracle/PRD/121/dbs/lkPRD_STDBY exclusive
sculkget: lock held by PID: 12057
ORA-09968: unable to lock file
ORA-1102 signalled during: alter database mount...