After BDA Upgrade DataNodes and NodeManagers are Down on Several Non-Critical Nodes When CentrifyDC is in Use (Doc ID 2275717.1)

Last updated on JUNE 11, 2017

Applies to:

Big Data Appliance Integrated Software - Version 4.5.0 and later
Linux x86-64

Symptoms

After BDA upgrade DataNodes(DN) and NodeManagers(NM) are found to be down on several non-critical nodes in environments using CentrifyDC.

1. The following alert is raised on the nodes:

The Cloudera Manager Agent is not able to communicate with this role's web server.

2. The /var/log/cloudera-scm-agent.log shows the agent is not able to monitor the web roles for DN/NM roles. The log reports:

HTTPError: HTTP Error 401: Authentication required
[10/Jun/2017 12:06:45 +0000] 15507 Monitor-GenericMonitor urllib2_kerberos CRITICAL GSSAPI Error: Unspecified GSS failure. Minor code
may provide more information/Server not found in Kerberos database
[10/Jun/2017 12:06:45 +0000] 15507 Monitor-GenericMonitor urllib2_kerberos CRITICAL GSSAPI Error: Unspecified GSS failure. Minor code
may provide more information/Server not found in Kerberos database
[10/Jun/2017 12:07:43 +0000] 15507 Monitor-GenericMonitor urllib2_kerberos CRITICAL GSSAPI Error: Unspecified GSS failure. Minor code
may provide more information/Server not found in Kerberos database
[10/Jun/2017 12:07:43 +0000] 15507 Monitor-GenericMonitor url_util ERROR Autentication error on attempt 1. Retrying after sleeping
1.000000 seconds.

 