"WARNING: Wrong OS disk s0 partition info" in Step 1 of BDA Mammoth V4.5/V4.6 OL6 on BDA Base Image 4.5.0-6

(Doc ID 2309143.1)

Last updated on SEPTEMBER 23, 2017

Applies to:

Big Data Appliance Integrated Software - Version 4.5.0 and later
Linux x86-64

Symptoms

Step 1 of a BDA v4.5.0 or v4.6.0 Mammoth install on a Base Image of 4.5.0-6 fails as below with partitions issuing messaging about the "primary" partition name.  This messaging will be raised for Node 1 on Step 1 of install, but during the reboot step on the rest of the nodes.

Note the issue here is not the same as that reported on OL6 in: Step 8 of OL5 Mammoth V4.8 Upgrade Raises "Wrong OS disk s0 partition info : 1 ext3 raid 2 ext3 raid 3 linux-swap 4 ext3 ext3" Running Validation Tests (Doc ID 2279524.1) or on OL5 in: Step 8 of OL5 Mammoth V4.8 Upgrade Raises "Wrong OS disk s0 partition info : 1 ext3 raid 2 ext3 raid 3 linux-swap 4 ext3 ext3" Running Validation Tests (Doc ID 2279524.1).  Although the symptoms here look similar this note describes a different issue than in those notes.

The same can be seen in /root/BDA_REBOOT_WARNINGS and in bdachecksw/bdacheckcluster at the time of the Mammoth failure.  Therefore this will affect Step 1, any reboots during the upgrade, which will generate /root/BDA_REBOOT_WARNINGS, and the final cluster health checks.

WARNING: Wrong OS disk s0 partition info : 1 ext4 ext4 boot 2 ext4 raid 3 linux-swap(v1) linux-swap 4 ext4 ext4
INFO: Expected OS disk s0 partition info : 1 ext3 raid 2 ext3 raid 3 linux-swap 4 ext3 primary or 1 ext3 primary raid 2 ext3 primary raid 3 linux-swap primary 4 ext3 primary or 1 ext4 primary boot 2 primary raid 3 linux-swap(v1) primary 4 ext4 primary
WARNING: Wrong OS disk s1 partition info : 1 ext4 ext4 boot 2 ext4 raid 3 linux-swap(v1) linux-swap 4 ext4 ext4
INFO: Expected OS disk s1 partition info : 1 ext3 raid 2 ext3 raid 3 linux-swap 4 ext3 primary or 1 ext3 primary raid 2 ext3 primary raid 3 linux-swap primary 4 ext3 primary or 1 ext4 primary boot 2 primary raid 3 linux-swap(v1) primary 4 ext4 primary
WARNING: Wrong data disk s2 partition info : 1 ext4 ext4
INFO: Expected data disk s2 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s3 partition info : 1 ext4 ext4
INFO: Expected data disk s3 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s4 partition info : 1 ext4 ext4
INFO: Expected data disk s4 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s5 partition info : 1 ext4 ext4
INFO: Expected data disk s5 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s6 partition info : 1 ext4 ext4
INFO: Expected data disk s6 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s7 partition info : 1 ext4 ext4
INFO: Expected data disk s7 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s8 partition info : 1 ext4 ext4
INFO: Expected data disk s8 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s9 partition info : 1 ext4 ext4
INFO: Expected data disk s9 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s10 partition info : 1 ext4 ext4
INFO: Expected data disk s10 partition info : "1 ext. primary" or "1 primary"
WARNING: Wrong data disk s11 partition info : 1 ext4 ext4
INFO: Expected data disk s11 partition info : "1 ext. primary" or "1 primary"

To confirm the issue verify:

To Confirm the issue do the following on Node 1 as 'root' user.

1. Verify the Mammoth version is 4.5 or 4.6.

2. Verify the 4.5.0-6 base image.

Verify the 4.5.0-6 rpm is installed as below:

a) Confirm the rpm in /root/Extras/BDA. 

 