Rebuild Function Based Index Online Fails With ORA-910
(Doc ID 2423908.1)
Last updated on JANUARY 07, 2025
Applies to:
Oracle Database Cloud Schema Service - Version N/A and laterOracle Database Exadata Cloud Machine - Version N/A and later
Oracle Cloud Infrastructure - Database Service - Version N/A and later
Oracle Database Cloud Exadata Service - Version N/A and later
Oracle Database Exadata Express Cloud Service - Version N/A and later
Information in this document applies to any platform.
Symptoms
Rebuild function based index online fails with ORA-00910: specified length too long for its datatype
max_string_size is standard, and sql_trace shows ORA-910 happened when creating table for journal table which uses raw(2410) column, length is greater than 2000
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Cause |
Solution |