Alter database convert to physical standby Fails ORA-38770 ORA-19899
(Doc ID 2848382.1)
Last updated on APRIL 17, 2023
Applies to:
Oracle Database - Enterprise Edition - Version 12.2.0.1 and laterInformation in this document applies to any platform.
Symptoms
Changes
Following Parameter was set in Standby
_allow_resetlogs_corruption= TRUE
This is an Unsupported parameter and doesnot check datafile header consistency and opens the database.
This parameter was set and database converted to Snapshot database.
This introduces the issue.
When the Database is converted back to Physical standby it considers the SCN of Flashback as Future SCN
Flashback Restore skipped because target SCN <SCN> is in future
Cause
To view full details, sign in with your My Oracle Support account. |
|
Don't have a My Oracle Support account? Click to get started! |
In this Document
Symptoms |
Changes |
Cause |
Solution |