Errors ORA-39014 ORA-39029 ORA-31672 On DataPump Import (Doc ID 464082.1)

Last updated on NOVEMBER 28, 2016

Applies to:

Oracle Database - Enterprise Edition - Version 10.2.0.3 and later
Information in this document applies to any platform.
***Checked for relevance on 16-Dec-2014***

Symptoms

Errors below appear when using DataPump import:

ORA-39014: One or more workers have prematurely exited.
ORA-39029: worker 6 with process name "DW06" prematurely terminated
ORA-31672: Worker process DW06 died unexpectedly.
Job "SYSTEM"."SYS_IMPORT_FULL_01" stopped due to fatal error at 00:59:40
ORA-39014: One or more workers have prematurely exited.

Cause