Error ORA-39125 When Using DataPump Import (IMPDP) (Doc ID 551528.1)

Last updated on SEPTEMBER 10, 2014

Applies to:

Oracle Database - Enterprise Edition - Version 10.1.0.5 and later
Information in this document applies to any platform.
***Checked for relevance on 10-Sep-2014***

Symptoms

DataPump import (impdp) fails with the following errors:

ORA-39125: Worker unexpected fatal error in KUPW$WORKER.PUT_DDLS while calling DBMS_METADATA.CONVERT []
ORA-06502: PL/SQL: numeric or value error
LPX-00210: expected '<' instead of 'n'

Cause