Data Pump Export Fails With ORA-39065, ORA-39078 and ORA-23603 Errors (Doc ID 785104.1)

Last updated on SEPTEMBER 27, 2016

Applies to:

Oracle Database - Enterprise Edition - Version 11.1.0.7 to 12.1.0.2 [Release 11.1 to 12.1]
Information in this document applies to any platform.
***Checked for relevance on 07-Apr-2015***

Symptoms

You are performing a Data Pump export (expdp), and it fails with the following errors:

ORA-39065: unexpected master process exception in RECEIVE
ORA-39078: unable to dequeue message for agent MCP from queue "KUPC$C_1_20090220124816"
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 95
ORA-06512: at "SYS.KUPC$QUE_INT", line 609
ORA-25205: the QUEUE SYS.KUPC$C_1_20090220124816 does not exist
Job "SYSTEM"."SYS_EXPORT_FULL_01" stopped due to fatal error at 14:21:39
ORA-39014: One or more workers have prematurely exited.
ORA-39029: worker 1 with process name "DW01" prematurely terminated
ORA-31671: Worker process DW01 had an unhandled exception.
ORA-39079: unable to enqueue message DG,KUPC$C_1_20090220124816,KUPC$A_1_20090220124822,MCP,35193,Y
ORA-06512: at "SYS.DBMS_SYS_ERROR", line 86
ORA-06512: at "SYS.KUPC$QUE_INT", line 969
ORA-23603: STREAMS enqueue aborted due to low SGA
ORA-06512: at "SYS.KUPW$WORKER", line 1602
ORA-06512: at line 2