Symptoms

ACTUAL BEHAVIOR

Find Implementing an ECO where you add a Standard Operations that is not a count point operation (Defined on the WIP tab under Operations) will implement as a standard operation with the count point flag checked.

EXPECTED BEHAVIOR

Expect count point to be unchecked after implementing the ECO.

STEPS
1) Create a standard operation with the count-point flag unchecked
2) Create an ECO and add the standard operation. Note that the count-point is unchecked on the ECO
3) Implement the ECO
4) Check the new routing. The Standard Operation will be checked as a count-point.
* The only way to fix this is to open the Standard Operations form and toggle the count point off then on and save.