Fte Factor on Salary Screen is not Changing when Standard Working Hours are Changed in Update Modus

(Doc ID 1541270.1)

Last updated on JUNE 20, 2017

Applies to:

Oracle HRMS (Netherlands) - Version 11.5.10.2 and later
Information in this document applies to any platform.
*** Checked for relevance: 16-Oct-2015 ***

Symptoms


Find that FTE Factor on the salary page is not always getting updated after updating standard conditions on assignment


STEPS TO REPRODUCE

Use responsibility : NL HRMS Manager
Navigation :people > enter and maintain
1.query person
2.press assignment
3.go to standard conditions tab
4.update regular working hours to 36
5. select UPDATE and save

The standard conditions tab now shows individual working hours remain as 40.00 part-time percentage is recalculated by system to 111.111 the salary page shows no change on fte factor

6. change part-time percentage to 90
regular working hours remains 36
individual working hours changed to 32.4
select CORRECTION as datetrack mode

the salary page shows FTE factor as 0.9 now



Cause