Version Control For Formula Approved For Laboratory Use Is Not Working. (Doc ID 1935385.1)

Last updated on NOVEMBER 05, 2016

Applies to:

Oracle Process Manufacturing Product Development - Version 12.1.3 and later
Information in this document applies to any platform.

Symptoms

On : 12.1.3 version,
ACTUAL BEHAVIOR
---------------
Setting formula Version control  to yes has no effect on formula of status approve for laboratory use
EXPECTED BEHAVIOR
-----------------------


To receive a caution message (APP-GMD-81401 : Choose OK if you would like a new version created , cancel if you wish to discard changes) when make a change in the formula

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. Product Development Security Manager > Organization Parameters > Formula > Version Control > Select 'Yes'.
2. Create a Formula and change status to "Approved for Laboratory Uses".
3. Do changes in Formula ,formula is saved  without receiving a caution message

Cause