CSCHTAB.pll , CSSRTSK.pll and OKSACTEV.pll Do Not Generate Successfully After Patch Application
(Doc ID 2007657.1)
Last updated on AUGUST 15, 2023
Applies to:
Oracle Teleservice - Version 12.2.4 and laterInformation in this document applies to any platform.
Symptoms
After applying patches on top of 12.2.4 there are errors compiling certain libraries and forms:
The following Oracle Forms objects did not generate successfully:
au resource CSCHTAB.pll (version: 120.122.12020000.28)
au resource CSSRTSK.pll (version: 120.204.12020000.39)
au resource OKSACTEV.pll (version: 120.4.12020000.3)
CSCHTAB.pll (120.122.12020000.28)
Compilation errors on CHARGE_BUTTONS:
PL/SQL ERROR 907 at line 0, column 0
cannot load library unit APPS.CS_CHARGE_DETAILS_PUB (referenced by APPS.CSD_PROCESS_UTIL)
PL/SQL ERROR 0 at line 671, column 32
Item ignored
PL/SQL ERROR 320 at line 675, column 4
the declaration of the type of this expression is incomplete or malformed
PL/SQL ERROR 0 at line 675, column 4
Statement ignored
PL/SQL ERROR 320 at line 676, column 4
the declaration of the type of this expression is incomplete or malformed
PL/SQL ERROR 0 at line 676, column 4
Statement ignored
PL/SQL ERROR 320 at line 677, column 4
the declaration of the type of this expression is incomplete or malformed
PL/SQL ERROR 0 at line 677, column 4
Statement ignored
PL/SQL ERROR 320 at line 685, column 10
the declaration of the type of this expression is incomplete or malformed
PL/SQL ERROR 0 at line 685, column 6
Statement ignored
Failed to generate library.
FRM-30312: Failed to compile the library.
CSSRTSK.pll (120.204.12020000.39)
Compilation errors on MULTIPLE_TIME_ZONE_SUPPORT:
PL/SQL ERROR 302 at line 2290, column 31
component 'CS_TIMEZONE_TZ' must be declared
PL/SQL ERROR 0 at line 2290, column 10
Statement ignored
PL/SQL ERROR 302 at line 2291, column 28
component 'CS_TIMEZONE_TZ' must be declared
PL/SQL ERROR 0 at line 2291, column 9
Statement ignored
Failed to generate library.
FRM-30312: Failed to compile the library.
OKSACTEV.pll (120.4.12020000.3)
Compilation errors on OKSACTEV_COUNTERS_EVENTS:
PL/SQL ERROR 907 at line 0, column 0
cannot load library unit APPS.CS_STD (referenced by APPS.CS_COUNTERS_PUB)
PL/SQL ERROR 0 at line 109, column 4
Statement ignored
Failed to generate library.
FRM-30312: Failed to compile the library.
Changes
Applied 12.2.4 patches.
Cause