R12: After Cloning, Manual Forms Compilation In R12 Fails With: FRM-91500 (Doc ID 2139073.1)

Last updated on MARCH 08, 2017

Applies to:

Oracle Applications Technology Stack - Version 12.1.3 and later
Information in this document applies to any platform.

Symptoms

After Cloning, Manual Forms Compilation In R12 fails With: FRM-91500: Unable to start/complete the build
Issue occurs with seeded and custom forms.

We were able to compile the forms using adadmin.
The issue is happening only when we try to compile the forms manually.

Able to compile forms after performing the work around documented in note: R12: Manual Forms compilation In R12 fails With: FRM-91500: Unable to start/complete the build <Note: 431324.1>
Comment the below lines and update as below in frmcmp or frmcmp_bach.sh
 #TNS_ADMIN=$ORACLE_HOME/network/admin
 #export TNS_ADMIN
 TNS_ADMIN=${TNS_ADMIN:-$ORACLE_HOME/network/admin}
 export TNS_ADMIN

However,  the document says when we apply the 10.1.2.3 patch (For 10.1.2 Patch 5456500: For 10.1.2.3 Patch 8528194) the issue will be fixed permanently, however the patch has already been applied but the issue is still exist.

Changes

 Cloned the instance.

Cause