BOM_BO_PVT Invalid After Applying Patch 23540666:R12.BOM.D or Patch 24298382:R12.BOM.D , Error PLS-00302 component 'CHECK_DISABLE_DATE' must be declared (Doc ID 2182753.1)

Last updated on SEPTEMBER 21, 2016

Applies to:

Oracle Bills of Material - Version 12.2.4 and later
Information in this document applies to any platform.

Symptoms

On : 12.2.5 version, Bills

Getting errors while applying <Patch 23540666>:R12.BOM.D or <Patch 24298382>:R12.BOM.D
 
ERROR
-----------------------
SQL> show errors
Errors for PACKAGE BODY APPS.BOM_BO_PVT:

LINE/COL ERROR
-------- -----------------------------------------------------------------
2969/6 PL/SQL: Statement ignored
2969/33 PLS-00302: component 'CHECK_DISABLE_DATE' must be declared

STEPS
-----------------------
The issue can be reproduced at will with the following steps:
1. While applying Patch 23540666:R12.BOM.D or Patch 24298382:R12.BOM.D > BOM_BO_PVT becomes invalid.

Changes

Versions that cause this issue -

BOM_BO_PVT /  BOMVBOMB.pls Version 120.11.12020000.4 &

BOM_VALIDATE_BOM_COMPONENT     BOMLCMPS.pls   120.3.12020000.8 
BOM_VALIDATE_BOM_COMPONENT     BOMLCMPB.pls   120.62.12020000.18 / 19 

'CHECK_DISABLE_DATE' in BOM_BO_PVT is missing in these versions of BOM_VALIDATE_BOM_COMPONENT

Cause